Mass Spectrometry Facility
The Mass Spectrometry Facility provides instrumentation for the analysis of organic compounds using mass spectrometry-based techniques. Users receive support on technical aspects and data processing.
The facility has a broad range of instruments used to perform a wide range of analyses.
Samples and analyses
The following examples show a small selection of possible sample matrices and analytes. They are intended to provide a flavor of the kind of measurements that can be performed on the facility’s instruments.
Example of samples
- Industrial and residential wastewater
- Biota
- Textiles and plastic
- Food
- Synthesized chemicals
Example of analytes
- Environmental pollutants
- Pharmaceuticals
- Additives
- Natural compounds
- Metabolites
Example of information that can be deducted
- Qualitative identification, non-targeted and targeted
- Quantification, targeted
- Structural characterization, e.g. protein and polymer folding, assembly of (supra) molecular complexes
Separation techniques
Liquid chromatography (LC)
- reversed phase
- normal phase
- HILIC
Gas chromatography (GC)
Ionization sources
- Electrospray ionization (ESI)
- Nano-electrospray ionization (nano-ESI)
- Atmospheric pressure chemical ionsization (APCI)
- Matrix-assisted laser desorption ionization (MALDI)
- Electron impact ionization (EI)
- Negative chemical ionization (NCI)
Detectors
- Triple Quadrupole mass spectrometer
- Orbitrap mass spectrometer
- Quadrupole Time-of-Flight mass spectrometer coupled to an Ion Mobility spectrometer
- Linear Ion Trap mass spectrometer
Available systems
Please find our available systems below
Orbitrap, coupled quadupole-ion-trap
- Dionex UltiMate 3000 UHPLC coupled to Q-Exactive Quadrupole-Orbitrap mass spectrometer
- Ionization using ESI or APCI
Synapt G2-S, Q-TOF
- Waters Aquity UPLC or MALDI coupled to a Waters Synapt G2-S Quadrupole-Time-of-Flight (QTOF) mass spectrometer coupled to a traveling wave Ion Mobility spectrometer
- Ionization using ESI or nano-ESI or MALDI
XEVO TQ-S, triple quad
- Waters Aquity UPLC coupled to a Waters XEVO TQ-S triple quadrupole mass spectrometer
- Ionization using ESI
Vantage TSQ, triple quad
- Thermo Accela 1250 HPLC coupled to a Thermo Vantage TSQ triple quadrupole mass spectrometer
- Ionization using ESI
LTQ, linear ion trap
- Shimadzu LC-2040C 3D HPLC coupled to a Finnigan LTQ Linear Ion Trap mass spectrometer
- Ionization using ESI
GC-MSMS, triple quad
- Varian 450 GC coupled to a Varian 320 Triple Quadrupole mass spectrometer
- Ionization using EI or NCI
Contact
- Visiting address
- A323
- Svante Arrhenius väg 16 C
Last updated: September 13, 2024