Stockholm university

Göran LidénAssociate Proffessor

Publications

A selection from Stockholm University publication database

  • Secondary Lip Flow in a Cyclone Separator

    2023. Dzmitry Misiulia, Göran Lidén, Sergiy Antonyuk. Flow Turbulence and Combustion 110 (3), 581-600

    Article

    Three secondary flows, namely the inward radial flow along the cyclone lid, the downward axial flow along the external surface of the vortex finder, and the radial inward flow below the vortex finder (lip flow) have been studied at a wide range of flow rate 0.22–7.54 LPM using the LES simulations. To evaluate these flows the corresponding methods were originally proposed. The highly significant effect of the Reynolds number on these secondary flows has been described by equations. The main finding is that the magnitude of all secondary flows decrease with increasing Reynolds number. The secondary inward radial flow along the cyclone lid is not constant and reaches its maximum value at the central radial position between the vortex finder external wall and the cyclone wall. The secondary downward axial flow along the external surface of the vortex finder significantly increases at the lowest part of the vortex finder and it is much larger than the secondary flow along the cyclone lid. The lip flow is much larger than the secondary inward radial flow along the cyclone lid, which was assumed in cyclone models to be equal to the lip flow, and the ratio of these two secondary flows is practically independent of the Reynolds number. 

    Read more about Secondary Lip Flow in a Cyclone Separator
  • Performance characteristics of a small scale cyclone separator operated in different flow regimes

    2022. Dzmitry Misiulia, Göran Lidén, Sergiy Antonyuk. Journal of Aerosol Science 163

    Article

    The flow pattern, cyclone pressure drop and particle penetration through a sampling cyclone have been studied at a wide range of flow rate 0.22–7.54 LPM using the LES simulations that have been validated based on experimental penetration data. The cyclone performance has been described by three dimensionless characteristics, the Euler number Eustatout, cut-size ψ50 and slope of the transformed penetration curve κ1. Three main flow regimes and four sub-regimes have been revealed. The effects of the flow rate (Reynolds number) on the dimensionless cyclone performance characteristics have been described and a one-term power series model has been proposed. Additionally, the effect of the aspiration efficiency on the cyclone cut-size has been determined.

    Read more about Performance characteristics of a small scale cyclone separator operated in different flow regimes
  • Evolution of Turbulent Swirling Flow in a Small-Scale Cyclone with Increasing Flow Rate: A LES Study

    2021. Dzmitry Misiulia, Göran Lidén, Sergiy Antonyuk. Flow Turbulence and Combustion 107, 575-608

    Article

    The flow field, vortex behaviour and pressure losses in a small-scale cyclone have been studied at a wide range of flow rate 0.23-39.7 NLPM (measured at 1 atm and 20 degrees C) using the LES simulations that have been validated based on experimental measurements of the cyclone pressure drop. The following flow characteristics such as (1) the radial distribution of the tangential velocity; (2) the maximum tangential velocity and axial downward flow rate; (3) natural vortex length and rotation frequency of the vortex end; and (4) pressure losses in the cyclone have been analysed as a function of Reynolds number. The radial distribution of the tangential velocity inside the cyclone has been described by a proposed equation for adapted Burger's vortex. The position of the lower end of the vortex (natural vortex length) as well as its rotational frequency have been investigated with the pressure sensing method. A unique vortex behaviour such as vortex end jump was revealed at some Reynolds numbers. Additionally, a deep analysis of the pressure losses in the cyclone has been performed which showed that the main pressure losses (up to 48%) occur in the vortex finder. Four flow regimes were revealed and a one-term power series model has been proposed to describe the effects of the Reynolds number on the Euler number (dimensionless pressure losses).

    Read more about Evolution of Turbulent Swirling Flow in a Small-Scale Cyclone with Increasing Flow Rate
  • Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment

    2017. Ana Maria Todea (et al.). Science of the Total Environment 605, 929-945

    Article

    Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of +/- 30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400 nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of +/- 50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400 nm can drastically bias the measurement results of all instruments and all metrics determined.

    Read more about Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment
  • Transport and Deposition of Welding Fume Agglomerates in a Realistic Human Nasal Airway

    2016. Lin Tian (et al.). Annals of Occupational Hygiene 60 (6), 731-747

    Article

    Welding fume is a complex mixture containing ultra-fine particles in the nanometer range. Rather than being in the form of a singular sphere, due to the high particle concentration, welding fume particles agglomerate into long straight chains, branches, or other forms of compact shapes. Understanding the transport and deposition of these nano-agglomerates in human respiratory systems is of great interest as welding fumes are a known health hazard. The neurotoxin manganese (Mn) is a common element in welding fumes. Particulate Mn, either as soluble salts or oxides, that has deposited on the olfactory mucosa in human nasal airway is transported along the olfactory nerve to the olfactory bulb within the brain. If this Mn is further transported to the basal ganglia of the brain, it could accumulate at the part of the brain that is the focal point of its neurotoxicity. Accounting for various dynamic shape factors due to particle agglomeration, the current computational study is focused on the exposure route, the deposition pattern, and the deposition efficiency of the inhaled welding fume particles in a realistic human nasal cavity. Particular attention is given to the deposition pattern and deposition efficiency of inhaled welding fume agglomerates in the nasal olfactory region. For particles in the nanoscale, molecular diffusion is the dominant transport mechanism. Therefore, Brownian diffusion, hydrodynamic drag, Saffman lift force, and gravitational force are included in the model study. The deposition efficiencies for single spherical particles, two kinds of agglomerates of primary particles, two-dimensional planar and straight chains, are investigated for a range of primary particle sizes and a range of number of primary particles per agglomerate. A small fraction of the inhaled welding fume agglomerates is deposited on the olfactory mucosa, approximately in the range 0.1-1%, and depends on particle size and morphology. The strong size dependence of the deposition in olfactory mucosa on particle size implies that the occupation deposition of welding fume manganese can be expected to vary with welding method.

    Read more about Transport and Deposition of Welding Fume Agglomerates in a Realistic Human Nasal Airway
  • An approach for manganese biomonitoring using a manganese carrier switch in serum from transferrin to citrate at slightly elevated manganese concentration

    2015. B. Michalke (et al.). Journal of Trace Elements in Medicine and Biology 32, 145-154

    Article

    After high-dose-short-term exposure (usually from occupational exposure) and even more under low-dose long term exposure (mainly environmental) manganese (Mn) biomonitoring is still problematic since these exposure scenarios are not necessarily reflected by a significant increase of total Mn in blood or serum. Usually, Mn concentrations of exposed and unexposed persons overlap and individual differentiation is often not possible. In this paper Mn speciation on a large sample size (n=180) was used in order to be able to differentiate between highly Mn-exposed or low or unexposed individuals at low total Mn concentration in serum (Mn(S)). The whole sample set consisted of three subsets from Munich, Emilia Romagna region in Italy and from Sweden. It turned out that also at low total Mn(S) concentrations a change in major Mn carriers in serum takes place from Mn-transferrin (Mn-Tf(S)) towards Mn-citrate (Mn-Cit(S)) with high statistical significance (p < 0.000002). This carrier switch from Mn-Tf(S) to Mn-Cit(S) was observed between Mn(S) concentrations of 1.5 mu g/L to ca. 1.7 mu g/L. Parallel to this carrier change, for sample donors from Munich where serum and cerebrospinal fluid were available, the concentration of Mn beyond neural barriers analysed as Mn in cerebrospinal fluid (Mn(C)) positively correlates to Mn-Cit(S) when Mn(S) concentration was above 1.7 mu g/L. The correlation between Mn-Cit(S) and Mn(C) reflects the facilitated Mn transport through neural barrier by means of Mn-citrate. Regional differences in switch points from Mn-Tf(S) to Mn-Cit(S) were observed for the three sample subsets. It is currently unknown whether these differences are due to differences in location, occupation, health status or other aspects. Based on our results, Mn-Cit(S) determination was considered as a potential means for estimating the Mn load in brain and CSF, i.e., it could be used as a biomarker for Mn beyond neural barrier. For a simpler Mn-Cit(S) determination than size exclusion chromatography inductively coupled plasma mass spectrometry (SEC-ICP-MS), ultrafiltration (UF) of serum samples was tested for suitability, the latter possibly being a preferred choice for routine occupational medicine laboratories. Our results revealed that UF could be an alternative if methodical prerequisites and limitations are carefully considered. These prerequisites were determined to be a thorough cleaning procedure at a minimum Mn(S) concentration >1.5 mu g/L, as at lower concentrations a wide scattering of the measured concentrations in comparison to the standardized SEC-ICP-MS results were observed.

    Read more about An approach for manganese biomonitoring using a manganese carrier switch in serum from transferrin to citrate at slightly elevated manganese concentration
  • Workplace aerosol mass concentration measurement using optical particle counters

    2012. Peter Goerner (et al.). Journal of Environmental Monitoring 14 (2), 420-428

    Article

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM (R) 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO (R)) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions calculated from the OPC data are closely correlated with the results of the particle size-selective sampling using the CIP 10. Furthermore, the OPC data allow calculation of the thoracic fraction of workplace aerosol (not measured by sampling), which is interesting in the presence of allergenic particles like fungi spores. The results also show that the modified COP inlet adequately samples inhalable aerosol in the range of workplace particle-size distribution.

    Read more about Workplace aerosol mass concentration measurement using optical particle counters
  • Correlation between airborne particle concentrations in seven industrial plants and estimated respiratory tract deposition by number, mass and elemental composition

    2011. Karine Elihn, Peter Berg, Göran Lidén. Journal of Aerosol Science 42 (2), 127-141

    Article

    The number and mass distribution of airborne particles were recorded in several industrial plants. From the data obtained, particle deposition was estimated in three regions of the respiratory tract using the ICRP grand average deposition model based on Hinds' (1999) parameterization. The median diameter was 30-70 nm (number distributions), and >4 mu m (mass distributions) near most work activities, resulting in linear relationships between the deposited number/mass concentrations and the number/mass concentrations in the air. Welding and laser cutting produced particles in the 200-500-nm range; total deposition was small, not in accordance with the linear relationship observed for the other work activities. The elemental content varied between particle sizes in some workplaces, causing different elements to deposit in different respiratory regions. Iron was the most abundant element in the particles in many of the workplaces; in an iron foundry, however, Fe was most abundant only in the micron-sized particles whereas the nanoparticles mainly comprised Pb and Sb.

    Read more about Correlation between airborne particle concentrations in seven industrial plants and estimated respiratory tract deposition by number, mass and elemental composition
  • The European Commission Tries to Define Nanomaterials

    2011. Göran Lidén. Annals of Occupational Hygiene 55 (1), 1-5

    Article

    In 2010, the European Commission held a short consultation on a proposed definition for nanomaterials, to be used in European Union legislation and programmes. This was in response to a European Parliament resolution, and the definition followed a proposal by one of the Commission's scientific committees. The definition has three parts: on size distribution, size of internal structural elements, and surface area; a material caught by any of these parts meets the definition. There are a number of problems. The definition seems to be written with engineered nanomaterials in mind but as written applies to non-supplied materials, such as smokes. The structural element component seems to capture items such as sunscreen and tennis rackets, which include nanomaterials. Use of the definition will require some international standards, which have yet to be written and which will involve some difficult decisions. It is understandable why there are both size and surface area requirements, but they are not wholly consistent. The Commission plans a further consultation in 2012, but it might be better to delay this until after the standardisation work.

    Read more about The European Commission Tries to Define Nanomaterials
  • Experimental investigation of the concept of a 'breathing zone' using a mannequin exposed to a point source of inertial/sedimenting particles emitted with momentum

    2010. Göran Lidén, Jüri Waher. Annals of Occupational Hygiene 54 (1), 100-116

    Article

    An inhaling mannequin, CALTOOL, was used in a specially ventilated room to compare the concentrations inhaled with those sampled by samplers mounted across the breathing zone. The CALTOOL is made from metal sheets and consists of a cylindrical torso (42 x 24 x 54 cm) with a circular cylinder as head. A circular nozzle simulates the mouth. This nozzle is part of a cassette that holds a filter. The inhalation rate is not periodic but kept constant at nominally 20 l min(-1). The CALTOOL was placed in a horizontal air stream ( approximately 10 cm s(-1)) either facing or back to the wind. In front of the lower chest of the CALTOOL, a particle source was mounted which emitted particles with a momentum directed upwards at an angle of 45 degrees towards the CALTOOL. Five monodisperse aluminium oxide powders were used as test aerosols. The mass median aerodynamic diameters of the test aerosols ranged approximately 10 to 95 mum. Six conically shaped aerosol samplers were mounted horizontally and over the breathing zone of the CALTOOL, one on each shoulder, three across the upper torso, and one at the lower torso centre. Four to six runs per test aerosol and CALTOOL orientation in the airflow were conducted. The samples were analysed gravimetrically. The concentration ratio aerosol sampler to the CALTOOL cassette was determined for the investigated mounting positions. The results showed that when the CALTOOL was exposed to particles emitted with momentum from a point source in front of the lower chest, the variation in concentration over the breathing zone was large. The ratio of the concentration sampled by an aerosol sampler mounted somewhere within the breathing zone to the CALTOOL cassette concentration, would, for specific particle sizes, easily differ by a factor of 3, but may extend up to 10-100, depending on the particular conditions. The basic concept of a breathing zone consisting of a hemisphere of radius 25-30 cm is therefore not well suited for workers handling a point source emitting large particles. For such sampling situations, it is suggested that the radius of the breathing zone is reduced to 10 cm, which may be achieved by a head-mounted sampler.

    Read more about Experimental investigation of the concept of a 'breathing zone' using a mannequin exposed to a point source of inertial/sedimenting particles emitted with momentum
  • Measured elemental carbon by thermo-optical transmittance analysis in water-soluble extracts from diesel exhaust, woodsmoke, and ambient particulate samples

    2010. Anna Wallén, Göran Lidén, Hans-Christen Hansson. Journal of Occupational and Environmental Hygiene 7 (1), 35-45

    Article

    Elemental carbon has been proposed as a marker of diesel particulate matter. The objective of this study was to investigate if water-soluble carbonaceous compounds could be responsible for positive bias of elemental carbon using NIOSH Method 5040 with a thermo-optical carbon transmittance analyzer. Filter samples from eight different aerosol environments were used: pure diesel exhaust fume with a high content of elemental carbon, pure diesel exhaust fume with a low content of elemental carbon, pure biodiesel exhaust fume, pure woodsmoke, an urban road tunnel, an urban street canyon, an urban background site, and residential woodburning in an urban area. Part of each filter sample was analyzed directly with a thermo-optical carbon analyzer, and another part was extracted with water. This water-soluble extract was filtered to remove particles, spiked onto filter punches, and analyzed with a thermo-optical transmittance carbon analyzer. The ratio of elemental carbon in the water-soluble extract to the particulate sample measurement was 18, 12, and 7%, respectively, for the samples of pure woodsmoke, residential woodburning, and urban background. Samples with diesel particulate matter and ambient samples with motor exhaust detected no elemental carbon in the water-soluble extract. Since no particles were present in the filtered water-soluble extract, part of the water-soluble organic carbon species, existing or created during analysis, are misclassified as elemental carbon with this analysis. The conclusion is that in measuring elemental carbon in particulate aerosol samples with thermo-optical transmittance analysis, woodsmoke, and biomass combustion samples show a positive bias of elemental carbon. The water-soluble EC could be used as a simple method to indicate other sources, such as wood or other biomass combustion aerosol particles.

    Read more about Measured elemental carbon by thermo-optical transmittance analysis in water-soluble extracts from diesel exhaust, woodsmoke, and ambient particulate samples
  • A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.

    2009. Göran Lidén, Jouni Surakka. Annals of Occupational Hygiene 53 (2), 99-116

    Article

    There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use and can be mounted inside modern, slimline welder's face shield. The mini sampler is based on a commercially available 13-mm filter holder that has been modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini sampler is 0.75 l min(-1). The mini sampler is to be worn mounted on a headset, modified from professional microphone headsets. Several aspects related to using the mini sampler have been tested by personal and static sampling at five workplaces and in the laboratory. Four headset models were tested for their suitability as a sampler holder, of which three models were accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler and the open-face 25-mm filter holder, respectively, depends on the size distribution of the sampled aerosol. At the lowest encountered mass concentration ratio of the open-face 25-mm filter holder to the IOM sampler (0.65), the sampling bias of the mini sampler versus the IOM sampler is approximately -26% and versus the open-face 25-mm filter holder is approximately +12%. For manganese, the negative root mean square (RMS) sampling bias of the mini sampler versus the IOM sampler is -0.046 and versus the open-face 25-mm filter holder is non-significant. Both these biases are statistically non-significant. The mini sampler can therefore be employed for determining welders' occupational exposure to manganese. The pressure drop across the filter can become excessive due to the small filtration area. Compared to the Casella Apex pump, the SKC AirChek2000 pump was generally found to be able to keep its flow rate constant within +/-5% at higher concentrations and for longer sampling times. Our results indicate that the inhalable fraction of the welding aerosol mass at the visited plants only consisted of 25-55% welding fume particles (agglomerates of coagulated particles generated by nucleation/condensation). The rest of the mass is made up of particles from spattering and grinding. More than 65% of manganese is generally found in the fume particles. The weighing precision of 13-mm filters is 2.2 microg. The RMS sample loss due to transport when loaded samples are shipped by mail in padded envelopes is 6 microg. Both figures are very low in comparison to the mass expected to be collected by personal sampling, generally exceeding 200 microg. The headset-mounted mini sampler is user-friendly, easy to adjust individually, does not disturb the welder during sampling and allows sampling inside personal protective equipment. The headset mounting arrangement improves personal sampling as it maintains the sampler close to the nose/mouth during the whole sampling period. This study shows that the developed headset-mounted mini sampler is suitable for assessing exposure to manganese in welding aerosol.

    Read more about A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.
  • A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    2009. Göran Lidén, Jouni Surakka. Journal of Physics, Conference Series 151 (1), 012041

    Article

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

    Read more about A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

Show all publications by Göran Lidén at Stockholm University